Workholding
Contact
Series
D8.753

Intensifier 21 cm³

intensification ratio 1 : 4
max. operating pressure 500 / 125 bar
single and double acting
Intensifier 21 cm³
Downloads
Catalogue sheet
Operating instructions
Information Series
Description
D 8.753 Hydraulic intensifiers

Application
Hydraulic intensifiers convert a hydraulic pressure on the primary side (input) into a higher pressure on the secondary side (output). This enables the use of the comparatively low pressure of machine tool hydraulics to pressurise a hydraulic cylinder with increased pressure.
The oil quantity to be transmitted is not important for the intensifiers of this data sheet. Only after oil supply of the hydraulic cylinder in the low-pressure range is affected, the piston of intensification will be activated according to its specification by an external valve control or by an integrated switching function.

Important notes
The intensification volume of intensifiers is 21 cm³. This is the reason why no hydraulic element, which functions only with high pressure, e.g. hydraulic accumulators with a gas-preload pressure of more than100 bar and an oil absorption exceeding 10 cm³, must be used in the high-pressure range. The intensification volume of 21 cm³ is only used to generate the high-pressure, i.e. the compressibility of the hydraulic oil (1% at a pressure increase of 150 bar) and the increase of volume of the high-pressure hoses (1cm³ per m at a pressure increase of 100 bar) has to be considered.
Complete air bleeding of the hydraulic system is very important.
The high-pressure part should be controlled by a pressure gauge.

The elements 8753 200, -201 and -203 can be equipped with a manifold-mounted pressure switch for machine tool interlock, when using 8753-202 the pressure switch will be integrated in the piping. The switching pressure should be adjusted to 80 % of the secondary pressure.
When using pressure intensifiers 8753 201 and 8753 202 pay attention that no liquids penetrate through venting port “Z”. The vent screw with sintered metal air filter can be removed and a vent hose can be connected, if required. 
Operating conditions, tolerances and other data see data sheet A 0.100.


Versions

  • double-acting intensifier for single-acting cylinders
  • double-acting intensifier with sequence valve for double-acting cylinders
  • single-acting intensifier with integrated sequence valve for single-acting cylinders
Products (4)
Loading…
type
with fixed high-pressure volume (4)
type
oil - oil (4)
functioning
hydraulic port
pipe thread (4)
type
high-pressure volume, approx. [cm3]
21 (4)
intensification
max. low pressure [bar]
max. high pressure [bar]
500 (4)
max. flow rate low pressure [l/min]
8 (4)
max. flow rate high pressure [l/min]
- (4)
Item no. CAD datatypetypefunctioninghydraulic port
Item no.
CAD data
type
with fixed high-pressure volume
type
oil - oil
functioning
double acting
hydraulic port
pipe thread
Properties
Item no.
CAD data
type
with fixed high-pressure volume
type
oil - oil
functioning
double acting
hydraulic port
pipe thread
Properties
Item no.
CAD data
type
with fixed high-pressure volume
type
oil - oil
functioning
single acting
hydraulic port
pipe thread
Properties
Item no.
CAD data
type
with fixed high-pressure volume
type
oil - oil
functioning
single acting
hydraulic port
pipe thread
Properties
Loading…
Item no.
type
with fixed high-pressure volume
type
oil - oil
functioning
double acting
hydraulic port
pipe thread
type
without sequence valve
high-pressure volume, approx. [cm3]
21
intensification
4
max. low pressure [bar]
125
max. high pressure [bar]
500
max. flow rate low pressure [l/min]
8
max. flow rate high pressure [l/min]
-
Item no.
type
with fixed high-pressure volume
type
oil - oil
functioning
double acting
hydraulic port
pipe thread
type
with sequence valve
high-pressure volume, approx. [cm3]
21
intensification
4
max. low pressure [bar]
125
max. high pressure [bar]
500
max. flow rate low pressure [l/min]
8
max. flow rate high pressure [l/min]
-
Item no.
type
with fixed high-pressure volume
type
oil - oil
functioning
single acting
hydraulic port
pipe thread
type
without sequence valve
high-pressure volume, approx. [cm3]
21
intensification
3.85
max. low pressure [bar]
130
max. high pressure [bar]
500
max. flow rate low pressure [l/min]
8
max. flow rate high pressure [l/min]
-
Item no.
type
with fixed high-pressure volume
type
oil - oil
functioning
single acting
hydraulic port
pipe thread
type
without sequence valve
high-pressure volume, approx. [cm3]
21
intensification
3.85
max. low pressure [bar]
130
max. high pressure [bar]
500
max. flow rate low pressure [l/min]
8
max. flow rate high pressure [l/min]
-
Accessories (6)
Item no. CAD data Description
Item no.
CAD data
Description
Input plate max. 500 bar, as per data sheet C2.360
Item no.
CAD data
Description
Series mounting plate for 1 directional control valve max. 500 bar, as per data sheet C2.360
Item no.
CAD data
/
Description
Series mounting plate for 2 valves as per data sheet D8.753
Item no.
CAD data
Description
Sequence valve ND 4 - G1/4 with check valve adjustment range: 10 to 150 bar max. 500 bar, as per data sheet C2.954
Item no.
CAD data
Description
Plug-type connector ND5 - Ø10 x 14 mm short version, with FKM seals max. 500 bar, as per data sheet F9.300
Item no.
CAD data
Description
Pressure switch, hydro-electric pressure adjustment range: 50-550 bar hydraulic connection: manifold mounting electrical connection: for plug max. 600 bar, as per data sheet F9.732